Source: openFDA drug labels; not evidence of FDA approval or GlobalRx stock. Label records are not unique products. Informational only—not medical advice.
Kcentra
Generic name: PROTHROMBIN, COAGULATION FACTOR VII HUMAN, COAGULATION FACTOR IX HUMAN, COAGULATION FACTOR X HUMAN, PROTEIN C, PROTEIN S HUMAN, AND WATER
NDC: 63833-386, 63833-387
Description
11 DESCRIPTION KCENTRA is a purified, heat-treated, nanofiltered and lyophilized non-activated four-factor Prothrombin Complex Concentrate (Human) prepared from human U.S. Source Plasma (21 CFR 640.60). It contains the Vitamin K dependent Coagulation Factors II, VII, IX and X, and the antithrombotic Proteins C and S. Factor IX is the lead factor for the potency of the preparation as stated on the vial label. The excipients are human antithrombin III, heparin, human albumin, sodium chloride, and sodium citrate. KCENTRA is sterile, pyrogen-free, and does not contain preservatives. The product contents are shown in Table 6 and listed as ranges for the blood coagulation factors. Table 6: Composition per Vial of KCENTRA Exact potency of coagulant and antithrombotic proteins are listed on the carton Ingredient Potency Range for 500 units Potency Range for 1000 units Total protein 120–280 mg 240–560 mg Factor II 380–800 units 760–1600 units Factor VII 200–500 units 400–1000 units Factor IX 400–620 units 800–1240 units Factor X 500–1020 units 1000–2040 units Protein C 420–820 units 840–1640 units Protein S 240–680 units 480–1360 units Heparin 8–40 units 16–80 units Antithrombin III 4–30 units 8–60 units Human albumin 40–80 mg 80–160 mg Sodium chloride 60–120 mg 120–240 mg Sodium citrate 40–80 mg 80–160 mg HCl Small amounts Small amounts NaOH Small amounts Small amounts All plasma used in the manufacture of KCENTRA is obtained from US donors and is tested using serological assays for hepatitis B surface antigen and antibodies to HIV-1/2 and HCV. The plasma is tested with Nucleic Acid Testing (NAT) for HCV, HIV-1, HAV, and HBV, and found to be non-reactive (negative), and the plasma is also tested by NAT for human parvovirus B19 (B19V) in order to exclude donations with high titers. The limit for B19V in the fractionation pool is set not to exceed 10 4 units of B19V DNA per mL. Only plasma that passed virus screening is used for production. The KCENTRA manufacturing process includes various steps, which contribute towards the reduction/inactivation of viruses. KCENTRA is manufactured from cryo-depleted plasma that is adsorbed via ion exchange chromatography, heat treated in aqueous solution for 10 hours at 60°C, precipitated, adsorbed to calcium phosphate, virus filtered, and lyophilized. Manufacturing steps were independently validated in a series of in vitro experiments for their virus inactivation / reduction capacity for both enveloped and non-enveloped viruses. Table 7 shows the virus clearance during the manufacturing process for KCENTRA, expressed as the mean log 10 reduction factor. Table 7: Mean Virus Reduction Factors [log 10 ] of KCENTRA Virus Studied Manufacturing Steps Heat treatment ("Pasteurization") Ammonium sulphate precipitation followed by Ca Phosphate adsorption 2 × 20 nm Virus Filtration Overall Virus Reduction [log 10 ] HIV Human immunodeficiency virus, a model for HIV-1 and HIV-2 BVDV Bovine viral diarrhea virus, model for HCV PRV Pseudorabies virus, a model for large enveloped DNA viruses WNV West Nile virus HAV Hepatitis A virus CPV Canine parvovirus, model for B19V n.d. not determined Enveloped Viruses HIV ≥ 5.9 ≥ 5.9 ≥ 6.6 ≥ 18.4 BVDV ≥ 8.5 2.2 ≥ 6.0 ≥ 16.7 PRV 3.8 7.2 ≥ 6.6 ≥ 17.6 WNV ≥ 7.4 n.d. ≥ 8.1 ≥ 15.5 Non-Enveloped Viruses HAV 4.0 1.8 ≥ 6.1 ≥ 11.9 CPV [0.5] Reduction factor below 1 log 10 was not considered in calculating the overall virus reduction. Studies using human parvovirus B19, which are considered experimental in nature, have demonstrated a virus reduction factor of 3.5 log 10 by heat treatment. 1.5 6.5 8.0
Indications and Usage
1 INDICATIONS AND USAGE KCENTRA, (Prothrombin Complex Concentrate (Human)), is a blood coagulation factor replacement product indicated for the urgent reversal of acquired coagulation factor deficiency induced by Vitamin K antagonist (VKA, e.g., warfarin) therapy in adult patients with: acute major bleeding or need for an urgent surgery/invasive procedure. KCENTRA, Prothrombin Complex Concentrate (Human), is a blood coagulation factor replacement product indicated for the urgent reversal of acquired coagulation factor deficiency induced by Vitamin K antagonist (VKA, e.g., warfarin) therapy in adult patients with: acute major bleeding or need for an urgent surgery/invasive procedure. ( 1 )
Dosage and Administration
2 DOSAGE AND ADMINISTRATION For intravenous use after reconstitution only. For intravenous use after reconstitution only. KCENTRA dosing should be individualized based on the patient's baseline International Normalized Ratio (INR) value, and body weight. ( 2.1 ) Administer Vitamin K concurrently to patients receiving KCENTRA to maintain factor levels once the effects of KCENTRA have diminished. The safety and effectiveness of repeat dosing have not been established and it is not recommended. ( 2.1 ) Administer reconstituted KCENTRA at a rate of 0.12 mL/kg/min (~3 units/kg/min) up to a maximum rate of 8.4 mL/min (~210 units/min). ( 2.3 ) Pre-treatment INR 2–< 4 4–6 > 6 Dose Dosing is based on body weight. Dose based on actual potency is stated on the vial, which will vary from 20--31 Factor IX units/mL after reconstitution. The actual potency for 500 unit vial ranges from 400-620 units/vial. The actual potency for 1000 unit vial ranges from 800-1240 units/vial. of KCENTRA (units Units refer to International Units. of Factor IX) / kg body weight 25 35 50 Maximum dose Dose is based on body weight up to but not exceeding 100 kg. For patients weighing more than 100 kg, maximum dose should not be exceeded. (units of Factor IX) Not to exceed 2500 Not to exceed 3500 Not to exceed 5000 2.1 Dosage Measurement of INR prior to treatment and close to the time of dosing is important because coagulation factors may be unstable in patients with acute major bleeding or an urgent need for surgery and other invasive procedures. Individualize KCENTRA dosing based on the patient's current pre-dose International Normalized Ratio (INR) value, and body weight (see Table 1 ). The actual potency per vial of Factors II, VII, IX and X, Proteins C and S is stated on the carton. Administer Vitamin K concurrently to patients receiving KCENTRA. Vitamin K is administered to maintain Vitamin K-dependent clotting factor levels once the effects of KCENTRA have diminished. The safety and effectiveness of repeat dosing have not been established and it is not recommended. Dose ranging within pre-treatment INR groups has not been studied in randomized clinical trials of KCENTRA. Table 1: Dosage Required for Reversal of VKA Anticoagulation in Patients with acute major bleeding or need for an urgent surgery/invasive procedure Pre-treatment INR 2–< 4 4–6 > 6 Dose Dosing is based on body weight. Dose based on actual potency is stated on the vial, which will vary from 20–31 Factor IX units/mL after reconstitution. The actual potency for 500 unit vial ranges from 400-620 units/vial. The actual potency for 1000 unit vial ranges from 800-1240 units/vial. of KCENTRA (units Units refer to International Units. of Factor IX) / kg body weight 25 35 50 Maximum dose Dose is based on body weight up to but not exceeding 100 kg. For patients weighing more than 100 kg, maximum dose should not be exceeded. (units of Factor IX) Not to exceed 2500 Not to exceed 3500 Not to exceed 5000 Example dosing calculation for 80 kg patient For example, an 80 kg patient with a baseline of INR of 5.0, the dose would be 2,800 Factor IX units of KCENTRA, calculated as follows based on INR range of 4–6, see Table 1 : 35 units of Factor IX/kg × 80 kg = 2,800 units of Factor IX required For a vial with an actual potency of 30 units/mL Factor IX, 93 mL would be given (2,800 U/30 U per mL = 93 mL) . Monitor INR and clinical response during and after treatment. In clinical trials, KCENTRA decreased the INR to ≤ 1.3 within 30 minutes in most subjects. The relationship between this or other INR values and clinical hemostasis in patients has not been established [see Clinical Studies (14) ]. 2.2 Preparation and Reconstitution Reconstitute KCENTRA using aseptic technique with 20 mL (nominal potency 500 U kit) or 40 mL (nominal potency 1000 U kit) of Sterile Water for Injection (diluent) provided in the kit. Do not use KCENTRA beyond the expiration date on the vial label and carton. KCENTRA is for single-dose only. Contains no preservatives. Discard partially used vials. Kcentra Reconstitution Instructions Ensure that the KCENTRA vial and diluent vial are at room temperature. Remove flip caps from the KCENTRA and diluent vials. Wipe the stoppers with the alcohol swab provided and allow to dry prior to opening the Mix2Vial package. Open the Mix2Vial package by peeling off the lid (Fig. 1). Do not remove the Mix2Vial from the blister package. Fig. 1 Place the diluent vial on an even, clean surface and hold the vial tight. Take the Mix2Vial together with the blister package and push the spike of the blue adapter end straight down through the diluent vial stopper (Fig. 2). Fig. 2 Carefully remove the blister package from the Mix2Vial set by holding at the rim, and pulling vertically upwards. Make sure that you only pull away the blister package and not the Mix2Vial set (Fig. 3). Fig. 3 Place the KCENTRA vial on an even and firm surface. Invert the diluent vial with the Mix2Vial set attached and push the spike of the transparent adapter end straight down through the KCENTRA vial stopper (Fig. 4). The diluent will automatically flow into the KCENTRA vial. Fig. 4 Note: If the vacuum in the KCENTRA vial is accidentally lost during reconstitution with the Mix2Vial device, the transfer with the Mix2Vial will not work. In this case, separate the set into two pieces as illustrated in Fig. 6 below; do not discard the diluent vial. Place the KCENTRA vial aside on a flat surface. Remove the blue adapter end from the diluent vial of the Mix2Vial set (Fig. 5) by lifting and bending the blue adapter to the side until it disconnects from the diluent vial. For reconstitution: Using a separate sterile needle and syringe, withdraw the remaining diluent. Remove the needle from the syringe. Attach the syringe to the transparent adapter of the KCENTRA vial as illustrated in Fig. 8 below, and transfer the entire diluent volume into the KCENTRA vial. Remove syringe. Gently swirl the KCENTRA vial to ensure the product is fully dissolved. Do not shake. Proceed to step 10. Fig. 5 With one hand, grasp the KCENTRA -side of the Mix2Vial set and with the other hand grasp the diluent-side and unscrew the set carefully counterclockwise into two pieces (Fig. 6). Discard the diluent vial with the blue Mix2Vial adapter attached. Fig. 6 Gently swirl the KCENTRA vial with the transparent adapter attached until the substance is fully dissolved (Fig. 7). Do not shake. Fig. 7 Draw air into an empty, sterile syringe. While the KCENTRA vial is upright, connect the syringe to the Mix2Vial's Luer Lock fitting by screwing clockwise. Inject air into the KCENTRA vial (Fig. 8). Fig. 8 While keeping the syringe plunger pressed, turn the system upside down and draw the solution into the syringe by pulling the plunger back slowly (Fig. 9). Fig. 9 Now that the solution has been transferred into the syringe, firmly hold on to the barrel of the syringe (keeping the syringe plunger facing down) and disconnect the transparent Mix2Vial adapter from the syringe by unscrewing counterclockwise (Fig. 10). Attach the syringe to a suitable intravenous administration set. Fig. 10 After reconstitution, administration should begin promptly or within 4 hours. If the same patient is to receive more than one vial, you may pool the contents of multiple vials. Use a separate unused Mix2Vial transfer set for each product vial. Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 2.3 Administration Do not mix KCENTRA with other medicinal products; administer through a separate infusion line. Visually inspect the reconstituted solution for particulate matter and discoloration prior to administration whenever solution and container permit. Reconstituted KCENTRA solution should be colorless, clear to slightly opalescent, and free from visible particles. Do not use if the solution is cloudy, discolored, or contains particulates. Use aseptic technique when administering KCENTRA. Administer at room temperature. Administer by intravenous infusion at a rate of 0.12 mL/kg/min (~3 units/kg/min), up to a maximum rate of 8.4 mL/min (~210 units/min). No blood should enter the syringe, as there is a possibility of fibrin clot formation.
Warnings and Cautions
5 WARNINGS AND PRECAUTIONS Hypersensitivity reactions may occur. If necessary, discontinue administration and institute appropriate treatment. ( 5.1 ) Arterial and venous thromboembolic complications have been reported in patients receiving KCENTRA. Monitor patients receiving KCENTRA for signs and symptoms of thromboembolic events. KCENTRA was not studied in subjects who had a thrombotic or thromboembolic (TE) event within the prior 3 months. KCENTRA may not be suitable in patients with thromboembolic events in the prior 3 months. ( 5.2 ) KCENTRA is made from human blood and may carry a risk of transmitting infectious agents, e.g., viruses, the variant Creutzfeldt-Jakob disease (vCJD) agent, and theoretically, the Creutzfeldt-Jakob disease (CJD) agent. ( 5.3 ) 5.1 Hypersensitivity Reactions Hypersensitivity reactions including flushing, urticaria, tachycardia, anxiety, angioedema, wheezing, nausea, vomiting, hypotension, tachypnea, dyspnea, pulmonary edema, and bronchospasm have been observed with KCENTRA . If severe allergic reaction or anaphylactic type reactions occur, immediately discontinue administration, and institute appropriate treatment. 5.2 Thromboembolic Risk/Complications Both fatal and non-fatal arterial thromboembolic events (including acute myocardial infarction and arterial thrombosis), and venous thromboembolic events (including pulmonary embolism and venous thrombosis) and disseminated intravascular coagulation have been reported with KCENTRA in clinical trials and post marketing surveillance [see Adverse Reactions (6) and Clinical Studies (14) ] . Patients being treated with VKA therapy have underlying disease states that predispose them to thromboembolic events. Reversing VKA therapy exposes patients to the thromboembolic risk of their underlying disease. Resumption of anticoagulation should be carefully considered following administration of KCENTRA and Vitamin K once the risk of thromboembolic events outweighs the risk of bleeding. Thromboembolic events occurred more frequently following KCENTRA compared to plasma in a randomized, plasma controlled trial in subjects requiring urgent reversal of VKA anticoagulation due to acute major bleeding, and the excess in thromboembolic events was more pronounced among subjects who had a history of prior thromboembolic event, although these differences were not statistically significant [see Adverse Reactions (6.1) and Clinical Studies (14) ]. In a postmarketing observational study, there was no significant difference in the risk of post-treatment thromboembolic events after receiving KCENTRA compared with plasma therapy for VKA-associated acute major bleeding [see Adverse Reactions (6.2) ] . Potential benefits of treatment with KCENTRA should be weighed against the potential risks of thromboembolic events [ see Adverse Reactions (6) ] . Patients with a history of thrombotic events, myocardial infarction, cerebral vascular accident, transient ischemic attack, unstable angina pectoris, severe peripheral vascular disease, or disseminated intravascular coagulation, within the previous 3 months were excluded from participating in the plasma-controlled RCT. KCENTRA may not be suitable in patients with thromboembolic events in the prior 3 months. Because of the risk of thromboembolism associated with reversal of VKA, closely monitor patients for signs and symptoms of thromboembolism during and after administration of KCENTRA [see 17 Patient Counseling Information ]. 5.3 Transmissible Infectious Agents Because KCENTRA is made from human blood, it may carry a risk of transmitting infectious agents, e.g., viruses, the variant Creutzfeldt-Jakob disease (vCJD) agent, and, theoretically, the Creutzfeldt-Jakob disease (CJD) agent. There is also the possibility that unknown infectious agents may be present in such products. Despite the use of two dedicated virus reduction steps in manufacturing to reduce risks, such products may still potentially transmit disease. Reports of suspected virus transmission of hepatitis A, B, C, and HIV were generally confounded by concomitant administration of blood/blood components and/or other plasma-derived products. No causal relationship to KCENTRA administration was established for any of these reports since introduction of a virus filtration step in 1996. All infections thought by a physician to have been possibly transmitted by KCENTRA should be reported by the physician or other healthcare provider to the CSL Behring Pharmacovigilance Department at 1-866-915-6958 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch .
Contraindications
4 CONTRAINDICATIONS KCENTRA is contraindicated in: Patients with known anaphylactic or severe systemic reactions to KCENTRA or any components in KCENTRA including heparin, Factors II, VII, IX, X, Proteins C and S, Antithrombin III and human albumin. Patients with disseminated intravascular coagulation (DIC). Patients with known heparin-induced thrombocytopenia (HIT). KCENTRA contains heparin [see Description (11) ] . KCENTRA is contraindicated in patients with: Known anaphylactic or severe systemic reactions to KCENTRA or any components in KCENTRA including heparin, Factors II, VII, IX, X, Proteins C and S, Antithrombin III and human albumin. ( 4 ) Disseminated intravascular coagulation. ( 4 ) Known heparin-induced thrombocytopenia. KCENTRA contains heparin. ( 4 )
Adverse Reactions
6 ADVERSE REACTIONS The most common adverse reactions (ARs) (frequency ≥2.8%) observed in subjects receiving KCENTRA were headache, nausea/vomiting, hypotension, and anemia. The most serious ARs were thromboembolic events including stroke, pulmonary embolism, and deep vein thrombosis. The following serious adverse reactions are described below and/or elsewhere in the labeling: Hypersensitivity Reactions [see Warnings and Precautions (5.1) ] Arterial and venous thromboembolic complications [see Boxed Warning and Warnings and Precautions (5.2) ] Possible transmission of infectious agents [see Warnings and Precautions (5.3) ] The most common adverse reactions (ARs) (frequency ≥ 2.8%) observed in subjects receiving KCENTRA were headache, nausea/vomiting, hypotension, and anemia. ( 6 ) The most serious ARs were thromboembolic events including stroke, pulmonary embolism, and deep vein thrombosis. ( 6 ) To report SUSPECTED ADVERSE REACTIONS, contact CSL Behring at 1-866-915-6958 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch. 6.1 Clinical Trials Experience Because clinical studies are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. Randomized, Plasma-Controlled Trial in Acute Major Bleeding In a prospective, randomized, open-label, active-controlled multicenter non-inferiority trial, 212 subjects who required urgent reversal of VKA therapy due to acute major bleeding were enrolled and randomized to treatment; 103 were treated with KCENTRA and 109 with plasma. Subjects with a history of a thrombotic event, myocardial infarction, cerebral vascular accident, transient ischemic attack, unstable angina pectoris, severe peripheral vascular disease, or disseminated intravascular coagulation, within the previous 3 months were excluded from participating. Subjects ranged in age from 26 years to 96 years. Randomized, Plasma-Controlled Trial in Urgent Surgery/Invasive Procedures In a prospective, randomized, open-label, active-controlled, multicenter non-inferiority trial, 176 subjects who required urgent reversal of VKA therapy due to the need for an urgent surgical or urgent invasive procedure were enrolled; 88 were treated with KCENTRA and 88 with plasma. Subjects ranged in age from 27 years to 94 years. Adverse reactions are summarized for KCENTRA and plasma in the Acute Major Bleeding and Urgent Surgery/Invasive Procedures RCTs ( see Table 2 ). Adverse Reactions are defined as adverse events that began during or within 72 hours of test product infusion plus adverse events considered possibly/probably related or related to study treatment according to the investigator, sponsor, or the blinded safety adjudication board (SAB), and with at least a 1.3‐fold difference between treatments. Table 2: Adverse Reactions Reported in more than 5 Subjects (≥2.8%) Following KCENTRA or Plasma Administration in RCTs No. (%) of subjects KCENTRA (N = 191) Plasma (N = 197) Nervous system disorders Headache 14 (7.3%) 7 (3.6%) Respiratory, thoracic, and mediastinal disorders Pleural effusion 8 (4.2%) 3 (1.5%) Respiratory distress/dyspnea/hypoxia 7 (3.7%) 10 (5.1%) Pulmonary edema 3 (1.6%) 10 (5.1%) Gastrointestinal disorders Nausea/vomiting 12 (6.3%) 8 (4.1%) Diarrhea 4 (2.1%) 7 (3.6%) Cardiac disorders Tachycardia 9 (4.7%) 2 (1.0%) Atrial fibrillation 8 (4.2%) 6 (3.0%) Metabolism and nutrition disorders Fluid overload Includes fluid overload and cardiac failure congestive 5 (2.6%) 16 (8.1%) Hypokalemia 9 (4.7%) 14 (7.1%) Psychiatric disorders Insomnia 9 (4.7%) 6 (3.0%) Vascular disorders Hypotension Includes orthostatic hypotension, hypotension, and hemorrhagic shock 14 (7.3%) 10 (5.1%) Injury, poisoning, and procedural complications Skin laceration/contusion/subcutaneous hematoma 8 (4.2%) 5 (2.5%) Blood and lymphatic disorders Anemia Includes anemia, hemoglobin decreased, and hematocrit decreased 11 (5.8%) 16 (8.1%) Serious adverse reactions in subjects receiving KCENTRA in both RCTs included ischemic cerebrovascular accident (stroke), DVT, thrombosis, and venous insufficiency. Serious adverse reactions in both RCTs for plasma included myocardial ischemia, myocardial infarction, fluid overload, embolic cerebral infarction, pulmonary edema, respiratory failure, and DVT. There were a total of 10 subjects (9.7%) who died in the KCENTRA group (1 additional death occurred on day 46 just after completion of the study reporting period) and 5 (4.6%) who died in the plasma group in the plasma-controlled RCT in acute major bleeding. The 95% confidence interval for the KCENTRA minus plasma between-group difference in deaths ranged from -2.7% to 13.5%. From the plasma-controlled RCT in urgent surgery/invasive procedures, there were a total of 3 subjects (3.4%) who died in the KCENTRA group (1 additional death occurred on day 48 after completion of the study reporting period) and 8 (9.1%) who died in the plasma group. The 95% confidence interval for the KCENTRA minus plasma between-group difference in deaths in this trial ranged from -14.6% to 2.7%. One death in the KCENTRA group in the RCT in Acute Major Bleeding and one death in the plasma group in the RCT in urgent surgery/invasive procedures were considered possibly related to study treatment according to an assessment of masked data by an independent safety adjudication board. No factors common to all deaths were identified, except for the frequent findings of a high comorbidity burden, advanced age, and death after being placed on comfort care. Although, a greater proportion of subjects in the RCT in acute major bleeding than in the RCT in surgery/invasive procedure received the highest two recommended doses of KCENTRA because more subjects in the trial in acute major bleeding had a baseline INR in the ranges of 4–6 and > 6.0, an analysis of deaths and factor levels in subjects with major bleeding revealed that subjects who died had similar median factor levels to subjects that did not die. Additionally, outliers with supraphysiologic factor levels did not have a mortality rate out of proportion to the overall population. Fluid Overload There were 9 subjects (4.7%, all non-related by investigator assessment) in the KCENTRA group who experienced fluid overload in the plasma-controlled RCTs in acute major bleeding and urgent surgery/invasive procedures and 25 (12.7%, 13 events related by investigator assessment) who had fluid overload in the plasma group. The 95% confidence interval for the KCENTRA minus Plasma between-group difference in fluid overload event incidence ranged from -14.1% to -2.0%. Subgroup analyses of the RCTs in acute major bleeding and urgent surgery/invasive procedures according to whether subjects with fluid overload events had a prior history of congestive heart failure are presented in Table 3. Table 3: Subjects with Fluid Overload Events by Prior History of Congestive Heart Failure in RCTs Subgroup Acute Major Bleeding Study Urgent Surgery/Invasive Procedures Study KCENTRA Plasma KCENTRA Plasma N Fluid Overload N (%) N Fluid Overload N (%) N Fluid Overload N (%) N Fluid Overload N (%) All subjects 103 6 (5.8) 109 14 (12.8) 88 3 (3.4) 88 11 (12.5) With history of CHF 46 4 (8.7) 44 11 (25.0) 24 1 (4.2) 36 6 (16.7) Without history of CHF 57 2 (3.5) 65 3 (4.6) 64 2 (3.1) 52 5 (9.6) Thromboembolic Events In RCTs, there were 13 subjects (6.8%) in the KCENTRA group who experienced possible thromboembolic events (TEEs) and 14 (7.1%) who had TEEs in the plasma group. The incidence of thromboembolic (TE) adverse reactions assessed as at least possibly related to study treatment by the Investigator or, in the case of serious thromboembolic events, the blinded safety adjudication board (SAB) was 9 (4.7%) in the KCENTRA group and 7 (3.6%) in the plasma group. When also considering the events which began during or within 72 hours of test product infusion, the incidence was 9 (4.7%) in the KCENTRA group and 8 (4.1%) in the plasma group. TE events observed in the acute major bleeding and the urgent surgery/invasive procedures RCTs are shown in Table 4. Table 4: Adverse Reactions (TEEs only) Following KCENTRA or Plasma Administration in RCTs No. (%) of subjects System Organ Class Acute Major Bleeding Study Urgent Surgery/Invasive Procedures Study KCENTRA (N = 103) Plasma (N = 109) KCENTRA (N = 88) Plasma (N = 88) Any possible TEE The tabulation of possible TEEs includes subjects with confirmed TEEs as well as 3 subjects in the Acute Major Bleeding RCT KCENTRA group that died of unknown causes on days 7, 31, and 38 and 1 subject in the Urgent Surgery/Invasive Procedures RCT plasma group that died of unknown causes on day 18. The death on day 7 was considered possibly related to study product by the SAB and is tabulated as an adverse reaction. 9 (8.7%) 6 (5.5%) 4 (4.5) 8 (9.1) TEE Adverse reactions 6 (5.5%) 4 (3.7%) 4 (4.5) 4 (4.5) Cardiac disorders Myocardial infarction 0 1 (0.9%) 0 2 (2.3) Myocardial ischemia 0 2 (1.8%) 0 0 Nervous system disorders Ischemic cerebrovascular accident (stroke) 2 (1.9%) 0 1 (1.1) 0 Embolic cerebral infarction 0 0 0 1 (1.1) Cerebrovascular disorder 0 1 (0.9%) 0 0 Vascular disorders Venous thrombosis calf 1 (1.0%) 0 0 0 Venous thrombosis radial vein 0 0 1 (1.1) 0 Thrombosis (microthrombosis of toes) 0 0 1 (1.1) 0 Deep vein thrombosis (DVT) 1 (1.0%) 0 1 (1.1) 1 (1.1) Fistula Clot 1 (1.0%) 0 0 0 Unknown Cause of Death (not confirmed TEE) Sudden death 1 (1.0%) 0 0 0 Subgroup analyses of the RCTs according to whether subjects with thromboembolic events had a prior history of a thromboembolic event are presented in Table 5. Table 5: Subjects with Thromboembolic Events by Prior History of TE Event in RCTs Acute Major Bleeding Study Urgent Surgery/Invasive Procedures Study KCENTRA Plasma KCENTRA Plasma N TE Events One additional subject in the Acute Major Bleeding RCT who had received KCENTRA, not listed in the table, had an upper extremity venous thrombosis in association with an indwelling catheter. Two additional subjects in the Urgent Surgery/Invasive Procedures RCT who had received KCENTRA, not listed in the table, had non-intravascular events (catheter-related/IVC filter insertion). N (%) N TE Events N (%) N TE Events N (%) N TE Events N (%) All subjects 103 9 (8.7) 109 6 (5.5) 88 4 (4.5) 88 8 (9.1) With history of TE event History of prior TE event greater than 3 months from study entry (TE event within 3 months not studied). 69 8 (11.6) 79 3 (3.8) 55 3 (5.5) 62 5 (8.1) Without history of TE event 34 1 (2.9) 30 3 (10.0) 33 1 (3.0) 26 3 (11.5) The European Bleeding and Surgical Study In a prospective, open label, single-arm, multicenter safety and efficacy trial, 17 subjects who required urgent reversal of VKA due to acute bleeding were enrolled and 26 subjects who required urgent reversal of Vitamin K antagonist due to the need for an urgent surgical/invasive procedure were enrolled, all were treated with KCENTRA. Subjects ranged in age from 22 years to 85 years. Serious adverse reactions considered possibly related to KCENTRA included a suspected pulmonary embolism which occurred in one subject following a second dose of KCENTRA. A single non-fatal TE event occurred in another KCENTRA-treated subject in that trial. 6.2 Postmarketing Experience In a postmarketing observational study, the risk of TEEs was assessed using Kaiser Permanente's databases in a matched, real-world cohort of hospitalized adults receiving either KCENTRA or plasma for VKA-associated major bleeding. For the primary analysis, 1119 KCENTRA patients and 1119 historical plasma patients with no recent history of TEEs were grouped in 1:1 individually matched cohort based on propensity scores. During the 45-day follow-up after acute VKA reversal, there was no statistically significant difference in the adjusted risk of TEEs between KCENTRA-treated patients and plasma-treated patients. . In a secondary analysis, 101 KCENTRA patients and 101 historical plasma patients with a recent history of TEEs diagnosed ≤90 days before study entry were also grouped in 1:1 individually matched cohort based on propensity scores. During the 45-day follow-up after acute VKA reversal, there was no statistically significant difference in the adjusted risk of TEEs between KCENTRA-treated patients and plasma-treated patients.
Selected label sections are shown. Read the complete official record for all labeling information.