Thrombin-JMI 50,000 units Powder for Topical Solution is an essential hemostatic agent used predominantly in surgical settings to facilitate clotting and reduce bleeding. Manufactured as a topical solution, Thrombin-JMI contains human thrombin, which plays a critical role in the clotting cascade by converting fibrinogen to fibrin.
Product Overview
Thrombin-JMI comes in a powder form that can be reconstituted into a solution for use. The product, identified by the NDC code 52604-7106, is designed for topical application during surgical procedures to control capillary, venous, and arteriolar bleeding.
Indications for Use
This hemostatic agent is indicated for use in surgery to aid in achieving hemostasis in patients who have an increased risk of bleeding or during procedures where conventional surgical techniques are insufficient.
Mechanism of Action
Thrombin-JMI functions by activating the final stage of the coagulation cascade. When applied to a bleeding site, it converts fibrinogen present in the patient's blood into fibrin, forming a stable clot that seals the wound.
Dosage and Administration
The product is supplied in vials containing 50,000 units of thrombin. The powder must be reconstituted with sterile isotonic saline solution just prior to use. Depending on the surgical site and the extent of bleeding, the amount of reconstituted solution applied can vary.
Clinical Efficacy
Clinical studies have demonstrated the efficacy of Thrombin-JMI in reducing intraoperative blood loss. For instance, a study published in PubMed reported that Thrombin-JMI significantly improved hemostatic outcomes in patients undergoing cardiothoracic surgery.
Safety and Side Effects
While generally safe, Thrombin-JMI can have side effects including localized pain or irritation at the application site. As with all human-derived blood products, there is a minimal risk of transmission of infectious agents, although stringent screening and processing methods are used to minimize this risk.
Storage and Handling
Thrombin-JMI should be stored at 2-8°C (36-46°F) and protected from light until ready to use. After reconstitution, the solution should be used immediately and not stored for future use.