Published GlobalRx articles · Historical product library

← Back to results

SureStep Pro High Control Solution: Clinical Profile and Applications

Historical source record created 2025-08-12 04:40:35. Preserved from the owner’s August 2025 backup; not a current clinical review.

The SureStep Pro High Control Solution, identified by NDC 53885-0793, serves as a critical tool in the calibration and quality assurance processes of blood glucose monitoring systems. Designed to ensure the accuracy of glucometers, this solution facilitates the validation of high glucose level readings, making it indispensable for healthcare providers striving for precise diabetes management.

Introduced to the market on October 15, 2007, and marketed by LifeScan, Inc., the SureStep Pro High Control Solution is classified under DEA Class 6 and is available by prescription only. Its legend status and controlled distribution underscore its specialized role within the medical field, ensuring it reaches only those healthcare professionals trained to use it correctly.

Utility in Clinical Settings

In clinical settings, the SureStep Pro High Control Solution is used to perform routine checks on blood glucose meters. By applying the solution, healthcare providers can confirm that their equipment measures glucose levels correctly at the higher end of the spectrum. This step is essential for maintaining the integrity of patient monitoring programs, where slight variations in measurement can significantly impact treatment protocols.

Regular use of this control solution contributes to patient safety by reducing the likelihood of misdiagnosis or incorrect treatment dosages due to equipment malfunctions. The solution's effectiveness is confirmed by its consistent performance in quality control assessments conducted across various healthcare facilities.

Regulatory and Safety Compliance

The SureStep Pro High Control Solution adheres to stringent safety and regulatory guidelines. Its discontinued status as of April 11, 2016, reflects LifeScan's commitment to product evolution and consumer safety. Users and providers are urged to follow replacement product guidelines to maintain the continuity of care and compliance with current medical standards.

This solution, while not currently available, has left a legacy of helping to maintain the high standards of glucometer accuracy in clinical practice.

Historical information only. Not medical advice, a treatment recommendation, evidence of FDA approval, or a statement of GlobalRx inventory. Consult a qualified healthcare professional and current original sources.