Published GlobalRx articles · Historical product library

← Back to results

Clinical Profile of the Paradigm 522NAP Insulin Pump with Link Monitor

Historical source record created 2025-08-12 04:25:34. Preserved from the owner’s August 2025 backup; not a current clinical review.

The Paradigm 522NAP Insulin Pump with Link Monitor (NDC9: 76300-0522) is a sophisticated medical device designed for the precise administration of insulin for diabetic management.

Developed by a leading marketer in diabetes care technologies, this insulin pump was introduced to the market on November 9, 2006, and remained available until December 31, 2016. The device is classified under Legend Status, indicating it is available by prescription only, and does not fall into restricted DEA classifications for its intended use in diabetes management.

Clinical Applications

The Paradigm 522NAP Insulin Pump is specifically tailored for diabetic patients requiring continuous insulin administration. It is suitable for both type 1 and insulin-dependent type 2 diabetes mellitus patients, offering a way to mimic the body's natural insulin release patterns more closely than traditional injection methods.

Features and Operation

Key features of the Paradigm 522NAP include its compact design and integration with a Link Monitor. This monitor facilitates remote monitoring, enhancing patient safety by enabling real-time data transfer to healthcare providers or caregivers.

The pump operates through a reservoir system which can be programmed to release insulin at set basal rates throughout the day, and also allows for bolus doses when required, for example, during meals. Users can adjust the settings manually or via the integrated monitor to adapt to changing needs in insulin dosage due to diet, activity, or other variables affecting blood glucose levels.

Clinical Efficacy

Clinical trials have demonstrated the effectiveness of continuous subcutaneous insulin infusion (CSII) devices like the Paradigm 522NAP in improving glycemic control. Studies indicate a reduction in HbA1c levels and a decrease in the frequency of hypoglycemic episodes in patients using CSII therapy.

A notable study (see study) found that the implementation of insulin pump therapy significantly increased time spent in the target glucose range compared to multiple daily injections in patients with type 1 diabetes.

Discontinuation and Replacement

Though the Paradigm 522NAP Insulin Pump with Link Monitor is no longer in production as of December 2016, its underlying technology continues to influence current insulin delivery systems. For patients still utilizing older devices, it is essential to review newer models that might offer enhancements and improved features to suit their medical needs.

Historical information only. Not medical advice, a treatment recommendation, evidence of FDA approval, or a statement of GlobalRx inventory. Consult a qualified healthcare professional and current original sources.