Published GlobalRx articles · Historical product library

← Back to results

Clinical Profile of Liletta 52mg/1unit Intrauterine Device

Historical source record created 2025-08-12 08:14:13. Preserved from the owner’s August 2025 backup; not a current clinical review.

Overview

Liletta 52mg/1unit Intrauterine Device is a long-acting reversible contraceptive (LARC) designed for insertion into the uterine cavity. This device releases levonorgestrel, a progestin hormone, to prevent pregnancy effectively for up to six years. Liletta is suitable for a wide range of patients seeking a reliable and low-maintenance birth control solution.

Mechanism of Action

The primary mechanism of Liletta involves the slow release of levonorgestrel, which thickens cervical mucus to impede sperm movement and alters the endometrial lining to reduce the likelihood of implantation. This dual action ensures a high level of contraception efficacy while being minimally invasive.

Indications for Use

Liletta is indicated for women who wish to prevent pregnancy for up to six years. It is particularly beneficial for those who desire a long-term contraceptive method with the convenience of minimal daily management. Furthermore, it is suitable for women who may not tolerate estrogen-containing contraceptives well due to its progestin-only composition.

Clinical Efficacy

Clinical trials have demonstrated that Liletta boasts a high contraceptive effectiveness rate. According to research published in Contraception Journal, the cumulative pregnancy rate at the end of one year of use is less than 0.5% among typical users, making it one of the most effective reversible contraceptive methods available.

Safety Profile

Liletta has a favorable safety profile backed by clinical data. The most common adverse reactions include irregular bleeding, amenorrhea, and device expulsion. Serious complications such as perforation of the uterus or pelvic inflammatory disease (PID) occur infrequently but are important considerations for both practitioners and patients.

Insertion and Removal

Insertion of Liletta should be performed by trained healthcare providers who can ensure correct placement within the uterus. Typically, the procedure takes only a few minutes and can be done in an outpatient setting. Removal of the device is straightforward and can be done at any time if a patient desires to discontinue its use or if the device reaches the end of its approved duration.

Historical information only. Not medical advice, a treatment recommendation, evidence of FDA approval, or a statement of GlobalRx inventory. Consult a qualified healthcare professional and current original sources.