Published GlobalRx articles · Historical product library

← Back to results

Clinical Profile: Kogenate FS with Vial Adaptor 1000units Powder for Injection

Historical source record created 2025-08-12 06:53:00. Preserved from the owner’s August 2025 backup; not a current clinical review.

Overview

Kogenate FS with Vial Adaptor 1000units is a recombinant antihemophilic factor specifically designed for intravenous administration. It is indicated for the treatment of hemophilia A, a condition characterized by the deficiency of clotting factor VIII.

Therapeutic Indications

Kogenate FS is utilized for both the control and prevention of bleeding episodes in patients with hemophilia A. It plays a crucial role in surgical and invasive procedures management and routine prophylaxis to reduce the frequency of spontaneous hemorrhage among patients with severe hemophilia A.

Clinical Efficacy

The efficacy of Kogenate FS has been evidenced through clinical trials, showcasing its ability to raise the plasma factor VIII activity in hemophilia A patients to therapeutic levels. A study involving patients with severe hemophilia A demonstrated the product's effectiveness in managing both spontaneous and trauma-induced bleeds, as well as its utility in surgical settings. Additionally, long-term prophylaxis with Kogenate FS has shown to significantly decrease the incidence of joint damage in pediatric and adult populations suffering from this condition.

Dosage and Administration

Kogenate FS is supplied as a lyophilized powder that requires reconstitution with Sterile Water for Injection prior to use. The dosage regimen is individualized based on the severity of the factor VIII deficiency, the patient's weight, and the clinical situation. Treatment may include on-demand therapy for bleeding episodes or regular prophylaxis to prevent recurrent bleeding. Administration is performed intravenously using the provided vial adapter to ensure safe and efficient reconstitution and delivery of the product.

Safety Profile

Kogenate FS exhibits a favorable safety profile with a low incidence of serious adverse events. The most common adverse reactions reported include headaches, dizziness, and local injection site reactions. Due to its production process, the risk of transmission of infectious agents is minimized. However, as with all plasma-derived products, the potential for allergic reactions exists and should be monitored closely.

Pharmacological Properties

Kogenate FS functions by temporarily replacing the missing clotting factor VIII, thereby enabling the blood to clot normally and control bleeding. This recombinant product has an elimination half-life of approximately 12 hours, necessitating frequent administration to maintain adequate factor VIII levels. Its pharmacokinetic profile is consistent across various patient demographics, facilitating standardized treatment protocols.

Regulatory and Quality Assurance

Manufactured under stringent quality control protocols, Kogenate FS adheres to regulatory standards for the production of recombinant human proteins. Its stability and purity ensure it remains efficacious and safe for use throughout its shelf life.

Historical information only. Not medical advice, a treatment recommendation, evidence of FDA approval, or a statement of GlobalRx inventory. Consult a qualified healthcare professional and current original sources.