Published GlobalRx articles · Historical product library
← Back to resultsIopamidol-370 Solution for Injection: A Detailed Clinical Profile
Historical source record created 2025-08-12 02:32:11. Preserved from the owner’s August 2025 backup; not a current clinical review.
Iopamidol-370 Solution for Injection is a non-ionic, low-osmolar contrast medium, primarily used for various radiological procedures to enhance the visualization of internal structures. This solution is characterized by its high iodine concentration of 370 mg/mL, making it suitable for a range of diagnostic imaging needs.
Clinical Applications
Iopamidol-370 is extensively used in radiology for procedures such as cerebral angiography, peripheral arteriography, coronary arteriography, and venography. Its properties make it an ideal choice for both adult and pediatric patients, ensuring clear diagnostic results across diverse clinical scenarios.
Pharmacological Properties
This solution's non-ionic nature reduces the risk of side effects compared to ionic contrast media. Iopamidol-370 does not significantly affect heart rate or blood pressure due to its low osmolarity, offering a safer profile during administration.
Safety Profile
Clinical studies have demonstrated that Iopamidol-370 has a low incidence of adverse reactions. Most common side effects include mild and transient phenomena such as warmth or a metallic taste. Serious reactions such as severe hypersensitivity are rare but documented. A comprehensive study published in PubMed highlights the safety profile of non-ionic contrast agents like Iopamidol in humans.
Dosage and Administration
The dosage of Iopamidol-370 varies based on the type of procedure and the patient's weight. For most adults, doses range between 50 mL to 200 mL, administered via intravenous injection. It is critical to adhere to the recommended guidelines to ensure patient safety and optimize diagnostic quality.
Considerations for Use
Before administration, healthcare providers must assess patients for any history of allergies, particularly to iodine or contrast media. Premedication with corticosteroids or antihistamines may be considered for patients at higher risk of an allergic reaction. Additionally, hydration status should be monitored to mitigate the risk of contrast-induced nephropathy.
Storage and Handling
Iopamidol-370 Solution for Injection should be stored at controlled room temperature, between 15°C to 30°C. It must be protected from light and not used if the solution is discolored or contains particulate matter.
Historical information only. Not medical advice, a treatment recommendation, evidence of FDA approval, or a statement of GlobalRx inventory. Consult a qualified healthcare professional and current original sources.