Published GlobalRx articles · Historical product library

← Back to results

Hemofil M Powder for Injection (1701-2000 Units): Clinical Profile

Historical source record created 2025-08-12 04:52:38. Preserved from the owner’s August 2025 backup; not a current clinical review.

Introduction to Hemofil M

Hemofil M Powder for Injection (1701-2000 units) is an advanced antihemophilic factor used in the management of hemophilia A. This product, containing factor VIII, is essential for individuals who lack this clotting factor, facilitating hemostasis during bleeding episodes.

Composition and Presentation

Hemofil M comes in a powdered form for injection, with each vial containing between 1701 and 2000 units of factor VIII. It is formulated to ensure high purity and efficacy, making it a reliable choice for medical practitioners treating hemophilia A.

Mechanism of Action

The active ingredient in Hemofil M, factor VIII, plays a critical role in blood clotting. It is activated when an injury occurs, promoting the aggregation of platelets and the formation of a fibrin clot to stop bleeding. Hemofil M replenishes deficient factor VIII, thereby restoring the clotting process in patients with hemophilia A.

Clinical Applications

Hemofil M is indicated for the control and prevention of hemorrhagic episodes in patients with hemophilia A. It is particularly useful in perioperative management to cover surgical procedures and during dental work. The product helps to reduce the risk of excessive bleeding and complications associated with invasive interventions.

Dosage and Administration

The dosage of Hemofil M depends on the severity of the factor VIII deficiency, the extent and location of the bleeding, and the patient's clinical condition. Typically, the dosage is calculated to achieve a plasma factor VIII activity level sufficient to stop bleeding. Administration involves reconstitution with the provided diluent and intravenous injection under sterile conditions.

Safety and Efficacy

Clinical studies have demonstrated the effectiveness of Hemofil M in managing bleeding in patients with hemophilia A. The product's safety profile includes minimal adverse reactions, mainly limited to mild hypersensitivity. Regular monitoring for the development of inhibitors to factor VIII is recommended.

Relevant Research

For further clinical insights, refer to a study on the use of factor VIII products in hemophilia A management here. This research includes human trials supporting the efficacy and safety considerations of Hemofil M.

Historical information only. Not medical advice, a treatment recommendation, evidence of FDA approval, or a statement of GlobalRx inventory. Consult a qualified healthcare professional and current original sources.