Published GlobalRx articles · Historical product library
← Back to resultsClinical Profile of Helixate FS 1000units Powder for Injection
Historical source record created 2025-08-12 07:36:48. Preserved from the owner’s August 2025 backup; not a current clinical review.
Helixate FS 1000units Powder for Injection is a pivotal medical product specifically indicated for the treatment of hemophilia A. This condition is characterized by the deficiency of Factor VIII, a key protein necessary for blood clotting. By providing the necessary Factor VIII, Helixate FS aids in the prevention and control of bleeding episodes.
Product Overview
Helixate FS, with an NDC9 of 00053-8133, is an innovator product manufactured by CSL Behring GmbH. It has been on the market since April 1, 2008. Each dose contains 1000 units of the drug.
Indications
Helixate FS is designated for:
- Prevention and control of bleeding in patients with hemophilia A (congenital Factor VIII deficiency).
- Surgical prophylaxis in patients with hemophilia A to prevent excessive bleeding during and after surgery.
Dosage and Administration
The dosing schedule is variable and tailored according to individual patient needs and the severity of bleeding. The drug is administered as an intravenous injection, ensuring the Factor VIII is directly integrated into the bloodstream for optimal efficacy. Clinical judgment and close monitoring of Factor VIII levels are critical to determine the appropriate dosage and frequency.
Pharmacodynamics
Helixate FS replenishes deficient or absent Factor VIII, thereby enabling hemostasis in patients with hemophilia A. The increase in Factor VIII levels leads to the formation of thrombin, fostering clot stabilization and halting bleeding.
Clinical Efficacy
Studies have demonstrated the effectiveness of Helixate FS in improving hemostasis. A clinical trial showed that after administration, there was a significant reduction in bleeding events among hemophilia A patients. Additionally, patients experienced a marked improvement in their quality of life related to reduced bleeding.
Further research is documented in studies like this one from PubMed: Clinical efficacy and safety of recombinant human coagulation factor VIII.
Adverse Reactions
Commonly reported adverse effects of Helixate FS may include headache, fever, and allergic reactions. Monitoring for anaphylactic responses is crucial, and the product should be discontinued if serious hypersensitivity is observed.
Important Considerations
Helixate FS is an innovator product, which means it is not a generic but the first of its kind. It falls under schedule VI of DEA classifications and requires e-prescribing, aligning with modern pharmaceutical practices.
Note that Helixate FS has a limited distribution status, necessitating targeted supply chain strategies in global medical logistics.
Off-Market Date
It is crucial to note that Helixate FS 1000units Powder for Injection is scheduled to be off the market as of November 29, 2023. Thus, buyers and suppliers must plan accordingly to address the potential discontinuation.
Historical information only. Not medical advice, a treatment recommendation, evidence of FDA approval, or a statement of GlobalRx inventory. Consult a qualified healthcare professional and current original sources.





