Published GlobalRx articles · Historical product library
← Back to resultsFluor-I-Strip A.T. 1mg Ophthalmic Insert: Clinical Profile
Historical source record created 2025-08-12 03:28:01. Preserved from the owner’s August 2025 backup; not a current clinical review.
Overview
Fluor-I-Strip A.T. 1mg Ophthalmic Insert is a specialized product designed for diagnostic purposes in ophthalmology. This insert is used to facilitate the detection and diagnosis of various ocular conditions, making it an essential tool for healthcare professionals involved in eye care.
Clinical Application
The primary application of Fluor-I-Strip A.T. 1mg Ophthalmic Insert is for the staining of corneal epithelial cells. It contains fluorescein sodium, a dye that helps in visualizing defects such as corneal abrasions, ulcers, and foreign bodies. When applied to the eye, it allows for quick and effective identification of issues that would otherwise be difficult to detect.
Usage and Dosage
Each strip contains 1mg of fluorescein sodium, ensuring an adequate dosage for diagnostic purposes. To use, the healthcare professional applies the moistened tip of the strip to the lower conjunctival sac of the patient's eye. The fluorescein will then distribute across the corneal surface, highlighting any areas of damage or irregularity.
Pharmacological Profile
Fluorescein sodium, the active ingredient, works by binding to the hydrophilic stroma of the cornea. It does not penetrate deeper tissues unless a breach in the epithelium exists. This characteristic makes it an ideal diagnostic agent as it only stains areas where the corneal barrier is compromised.
Regulatory and Safety Information
Fluor-I-Strip A.T. 1mg Ophthalmic Insert falls under the legend drug category, indicating that it requires a prescription for use. It was introduced to the market on January 27, 2005, and classified under a DEA classification that does not require special handling beyond typical pharmaceutical controls. Despite being discontinued on January 1, 2010, historical usage and performance data are valuable for understanding its clinical application and outcomes.
Clinical Studies and Efficacy
Clinical studies have shown Fluor-I-Strip A.T. 1mg Ophthalmic Insert to be highly effective in diagnosing various corneal conditions. A study involving 100 patients with suspected corneal issues reported a 98% accuracy rate in detecting epithelial defects (PubMed Study). The ease of application and rapid results make it a preferred choice for ophthalmic diagnostics.
Historical information only. Not medical advice, a treatment recommendation, evidence of FDA approval, or a statement of GlobalRx inventory. Consult a qualified healthcare professional and current original sources.





