Published GlobalRx articles · Historical product library
← Back to resultsClinical Profile of AK-Spore HC Ophthalmic Suspension
Historical source record created 2025-08-12 01:18:38. Preserved from the owner’s August 2025 backup; not a current clinical review.
Overview of AK-Spore HC
AK-Spore HC Ophthalmic Suspension, listed under NDC 17478-0231, is a discontinued product previously available for ophthalmic use. Its formulation comprises hydrocortisone 1%, neomycin sulfate 0.35%, and polymyxin B sulfate 10,000 units per mL. This suspension was indicated for the treatment of steroid-responsive inflammatory ocular conditions when susceptible bacterial infections or a risk of bacterial ocular infection exists.
Indications
AK-Spore HC Ophthalmic Suspension was designated for patients suffering from ocular inflammation where corticosteroid therapy is indicated, combined with risks of bacterial infection or the presence of such infections. The combination of hydrocortisone, neomycin, and polymyxin B was designed to reduce inflammation and combat bacterial infections concurrently, ensuring a comprehensive approach to eye health.
Mechanism of Action
Hydrocortisone in AK-Spore HC works as an anti-inflammatory agent by inhibiting the release of substances in the body that cause inflammation. Neomycin and polymyxin B are both antibiotics, targeting a range of gram-negative and some gram-positive bacteria to mitigate the risk or presence of bacterial infections in the eye.
Pharmacokinetics
While exact pharmacokinetic data on AK-Spore HC is limited due to its discontinued status, the properties of its active ingredients can be understood from their general profiles. Hydrocortisone has variable ocular bioavailability and can be absorbed systemically to a small extent, potentially affecting adrenal function with prolonged use. Neomycin and polymyxin B primarily remain localized within the eye, though systemic absorption in very minimal amounts can occur.
Contraindications
AK-Spore HC Ophthalmic Suspension was contraindicated in patients with known hypersensitivity to any component of the product, viral diseases of the cornea and conjunctiva including epithelial herpes simplex keratitis (dendritic keratitis), vaccinia, and varicella, as well as mycobacterial infection of the eye and fungal diseases of ocular structures.
Adverse Reactions
Reported adverse reactions from AK-Spore HC included potential for ocular hypertension or glaucoma with possible optic nerve damage, posterior subcapsular cataract formation, and delayed wound healing with prolonged use. Additionally, allergic reactions, increased sensitivity to light, and the possibility of superinfection if resistant organisms proliferate could also occur.
Discontinuation
AK-Spore HC Ophthalmic Suspension was taken off the market on May 24, 2005. The specific reasons for its discontinuation were not publicly disclosed, though such decisions typically involve a combination of factors such as market demand, cost of production, regulatory changes, or introduction of alternative therapies with improved efficacy or safety profiles.
Historical information only. Not medical advice, a treatment recommendation, evidence of FDA approval, or a statement of GlobalRx inventory. Consult a qualified healthcare professional and current original sources.